ORGANOLEPTIC AND HALITOMETRIC ASSESSMENTS DO NOT CORRELATE WELL IN INTRA-ORAL HALITOSIS: A SYSTEMATIC REVIEW AND META-ANALYSIS.

Published
September 10, 2023
Journal
The journal of evidence-based dental practice
PICOID
d9acd50a
DOI
Citations
3
Keywords
H(2)S, Halitometer, Malodor, Organoleptic assessment, Sensitivity, Volatile sulfur compounds
Copyright
Copyright © 2023 The Author(s). Published by Elsevier Inc. All rights reserved.
Patients/Population/Participants

adult populations, patients with oral halitosis

Intervention

organoleptic measurement, device-supported methods

Comparison

halitometers

Outcome

correlation coefficient, specificity, sensitivity

Abstract

P
I
C
O

The gold standard method for diagnosing oral halitosis is the subjective organoleptic measurement. Device-supported methods are also widespread worldwide. The challenges and safety concerns around performing organoleptic measurements during pandemics and the diversity of measuring device alternatives raised our clinical question: which halitometer is the most suitable for diagnosing halitosis? This systematic review was registered in PROSPERO (ID CRD42022320024). The search was performed on March 23, 2022 in the following electronic databases: MEDLINE, Embase, Scopus, Web of Science, and CENTRAL. Adult populations with or without halitosis were included, and patients with systemic diseases were excluded. Organoleptic (subjective) measurement and the device-supported (objective) methods were compared; the primary outcome was the correlation coefficient, and the secondary was the specificity and sensitivity of the devices. QUADAS-2 and QUADAS-C were used to evaluate the risk of bias in the studies. Random-effects meta analyses were performed on the outcomes, and the secondary outcomes were plotted on a common ROC plot. A total of 1231 records were found in the 5 databases. After the selection process, 76 articles were eligible for the systematic review, and 14,635 patients were involved in the qualitative analysis. The pooled Spearman's correlation coefficient (c.c.) for sulfide monitors was 0.65; 95% CIs: [0.53-0.74]; I None of the most commonly used halitometers proved to be significantly superior to the others. Halimeter and OralChroma measurements did not correlate well with the organoleptic level of oral halitosis in adults. Therefore, better halitometers need to be developed as an alternative to organoleptic measurements.

Similar article map

CEO: Hwi-yeol YunCOO: Jung-woo ChaeCTO: Sangkeun Jung
Location: 204, W6, Chungnam National University, 99, Daehak-ro, Yuseong-gu, Daejeon, Republic of Korea
Tel: 042-821-7328E-mail: webmaster@lilac-co.kr
Copyright © 2024 by LiLac. All Rights Reserved.