Factors associated with diagnostic accuracy, technical success and adverse events of endoscopic ultrasound-guided fine-needle biopsy: A systematic review and meta-analysis.

Published
February 01, 2020
Journal
Journal of gastroenterology and hepatology
PICOID
b0eeacd5
DOI
Citations
21
Keywords
FNB, adverse event rate, diagnostic accuracy rate, technical success rate
Copyright
© 2020 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.
Patients/Population/Participants

patients with lesions within or adjacent to the digestive tract

Intervention

EUS-FNB using a 22G needle

Comparison

EUS-FNB using other needle sizes

Outcome

diagnostic accuracy rate, technical success rate, adverse event rate

Abstract

P
I
C
O

Endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) is used to diagnose lesions within or adjacent to the digestive tract. However, there is no report on the overall diagnostic accuracy, technical success, and adverse events of FNB. The aims of this study were to conduct a systematic review and meta-analysis to comprehensively assess the diagnostic accuracy, technical success, and adverse events of FNB. Pubmed, Embase, and Cochrane Library databases were searched for relevant articles published in English from January 1998 to May 2019 (No. CRD42019141647). Primary outcomes were EUS-FNB related diagnostic accuracy rate, technical success rate, and adverse event rate. A total of 51 articles including 5330 patients met our criteria. The overall EUS-FNB related diagnostic accuracy rate, technical success rate, and adverse event rate was 90.82% [95% confidence interval (CI) 88.69-92.76%], 99.71% [95% CI 99.35-99.93%], and 0.59% [95% CI 0.29-1.0%], respectively. Biopsy with 22G needle could increase the diagnostic accuracy rate and technical success rate to 92.17% [95% CI 89.32-94.61%] and 99.88% [95% CI 99.64-99.99%], respectively, and decrease the adverse event to 0.37% [95% CI 0.08-0.87%]. Moreover, it showed that 22G needle was an independent factor associated with a higher diagnostic accuracy rate and technical success rate and a lower adverse event rate (P = 0.04, P < 0.001, and P = 0.04, respectively) by univariate and multivariate meta-regression analyses. Endoscopic ultrasound-guided fine-needle biopsy is a feasible and safe procedure for lesions within or adjacent to the digestive tract. Biopsy using 22G needle could increase the diagnostic accuracy rate and technical success rate and decrease adverse event rate during the FNB procedure.

Similar article map

CEO: Hwi-yeol YunCOO: Jung-woo ChaeCTO: Sangkeun Jung
Location: 204, W6, Chungnam National University, 99, Daehak-ro, Yuseong-gu, Daejeon, Republic of Korea
Tel: 042-821-7328E-mail: webmaster@lilac-co.kr
Copyright © 2024 by LiLac. All Rights Reserved.