Meta-Analysis on the Impact of Coronary Bypass Graft Markers on Angiographic Procedural Outcomes.
patients with previous CABG
coronary artery bypass graft (CABG) markers
with and without radio-opaque markers
fluoroscopy time, amount of contrast, and duration of angiography
Abstract
Utilization of radio-opaque coronary artery bypass graft markers is known to decrease the amount of contrast dye required to complete the procedure. The practice of marking bypass grafts varies significantly among surgeons. Limited data exist comparing the outcomes of percutaneous coronary intervention with and without coronary artery bypass graft (CABG) markers. We sought to explore the impact of proximal radio-opaque markers placed during CABG in subsequent percutaneous coronary intervention procedural risks. In our understanding of the current literature, this is the first meta-analysis conducted to evaluate the association between procedural angiographic metrics and CABG radio-opaque markers. We performed a query of MEDLINE and Scopus databases through August 2022 to identify relevant studies evaluating procedural metrics among patients with previous CABG with and without radio-opaque markers who underwent angiography. The primary outcomes of interest were fluoroscopy time, amount of contrast, and duration of angiography. We identified a total of 4 studies with 2,046 patients with CABG (CABG with markers n = 688, CABG without markers n = 1,518).