Structural valve degeneration of bioprosthetic aortic valves: A network meta-analysis.

Published
February 27, 2022
Journal
The Journal of thoracic and cardiovascular surgery
PICOID
7ae50da2
DOI
Citations
10
Keywords
SAVR, Trifecta, bioprosthetic valve, meta-analysis, surgical aortic valve replacement
Copyright
Copyright © 2022 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Patients/Population/Participants

TF valve, Perimount valve, Carpentier-Edwards Perimount Magna Ease (ME) valve, Mitroflow valve

Intervention

Surgical aortic valve replacement

Comparison

TF valve vs. ME valve, TF valve vs. Perimount valve, TF valve vs. Mitroflow valve

Outcome

Structural valve degeneration (SVD) or reintervention due to SVD, All-cause reintervention

Abstract

P
I
C
O

To compare the rate of structural valve degeneration (SVD) following surgical aortic valve replacement associated with the Trifecta (TF) valve (St Jude Medical) versus other bioprosthetic valves. A systematic literature search was conducted for studies comparing durability of the TF prosthesis to other valve types, including Perimount (Edwards Lifesciences), Carpentier-Edwards Perimount Magna Ease (ME) (Edwards Lifesciences), and Mitroflow (LivaNova USA) after surgical aortic valve replacement. Random effect pairwise and network meta-analyses were performed to compare the incident rate ratio of the composite primary outcome of SVD or reintervention due to SVD. Ten studies with 31,029 patients were included, of whom 6832 received TF, 19,023 received Perimount, 3514 received ME, and 713 received Mitroflow. When compared with TF, ME was associated with lower rates of SVD or reintervention for SVD (incident rate ratio, 0.13; 95% CI, 0.02-0.92; P = .04). Similarly, at network meta-analysis, when compared with TF, only ME was associated with significantly lower rates of SVD or reintervention for SVD (incident rate ratio, 0.13; 95% CI, 0.02-0.97). ME (incident rate ratio, 0.18; 95% CI, 0.07-0.47) and PM (incident rate ratio, 0.34; 95% CI, 0.12-0.98) were associated with significantly lower rate of all-cause reintervention when compared with TF. No differences in the other secondary outcomes were found. The TF valve is associated with significantly higher rates of SVD or reintervention for SVD than the ME valve, but not the Mitroflow valve. The TF valve was also associated with higher rates of all-cause reintervention than ME and Perimount valves. The underlying mechanism(s) of these findings warrant further investigation.